The 100 Series of Low Profile Load Cells has been designed to suit a wide range of applications including high accuracy load weighing, fatigue testing, component and structural test rigs and general purpose laboratory force measurement testing.
Now Available with In-line conditioning modules 0-5V, 0-10V, +/-10V, 4-20mA. PC-USB, Handheld Display (Amp4) and Wireless Transmitter (Amp7-TxMIDI) only available on cable version.
100 series low profile load cell data sheet.pdf
(opens in a new window)
Standard Ranges | 0 to 100, 200, 300kN |
Excitation Voltage | 10V (normal), 15V (max) DC* |
Sensitivity | 2.0 mV/V (Nominal)* |
Non-Linearity | 0.05% of F.R.O or Better |
Hysteresis | 0.03% of F.R.O or Better |
Zero Balance | 0.5% of F.R.O or Better |
Bridge Resistance | 350 Ohm (8 Gauge Bridge) |
Over Load Characteristics | 150% Safe Overload 200% Ultimate Overload |
Insulation Resistance | > 2000M Ohm |
Storage Temp | -40 to +70 C |
Operating Temp | -20 to +70 C |
Compensated Temp | +20 to +70 C |
Electrical Connections | Connector - Amphenol MIL Spec Or Integral Screened Cable |
Thermal Sensitivity | 0.005% of F.R.O/C or better |
*Load Cells With USB or Amplified Modules click here for specifications
Capacity | A | B | C | D | E | F | Weight |
0 to 100, 200, 300kN | 155.0 | 60.0 | 48.0 | 3.5 | M36x2.0 | 12 x 11.0 on 130.0 PCD | 4.50 kg |
Improved Performance
Improved Thermal Characteristics
UKAS Calibration (previously NAMAS)
Connector or Cable
Connector Pin:
A - Excitation (+V)
B - Excitation (-V)
C - Output (+V)
D - Output (-V)
Cable:
Red - Excitation (+V)
Blue - Excitation (-V)
Green - Output (+V)
Yellow - Output (-V)
(Output In Compression)
Load Button
Base Plate
Location Ring