Load Cell In Line USB Miniature In Line USB module. This module allows you to plug your load cell directly into your PC/Laptop via the USB port. Data can then be viewed and logged on your PC. The logged data can be loaded into Excel and many other spreadsheets to produce graphical reports etc. Multiple load cells can be connected to your PC in this way and our free software allows you to display and log of up to 24 channels simultaneously (maximum channels may be dependent on PC). Power to the load cell is supplied by the USB port so no external power supply is needed. See below for PC screen shots. (Dimensions: 56mm x 31mm x 12mm - cable length from USB connector to module 150mm - total cable length is as selected in termination option) 
Load Cell In Line Amplifier Miniature In Line Load Cell Amplifier. This module amplifies the load cell signal into a number of more usable Outputs. Outputs available are 0-5V, 0-10V, +/-10V and 4-20mA. (Dimensions: 25mm Diameter x 12mm - normal cable length from load cell to module 150mm [call if you'd like a different configuration] - total cable length is as selected in termination option).

 

PC-USB Module

Parameter Min Typical Max Units/Notes
Supply Voltage Range (powered by PC)
4.35 5 5.25 Volts
Average Operational Current (normal mode)
70 80 mA@350 Ohm
Operating Temperature Range -40
85 Deg C
Storage Temperature Range -40
85 Deg C
Humidity 0
95 %RH
Bridge Measurement
Measurement Min Typical Max Units
Offset Temperature Stability
5 10 ppm/C
Gain Temperature Stability
30 50 ppm/C
Offset Stability with Time
35 160 ppm of FR
Gain Stability with Time

300 ppm of FR
Non Linearity before Linearization
5 25 ppm of FR
Internal Resolution
16 Million
Counts/Divs
Resolution @ 1Hz Readings (Noise Stable) over 100s
66,000
Counts/Divs
Resolution @ 10Hz Readings (Noise Stable) over 100s
40,000
Counts/Divs
Resolution @ 100Hz Readings (Noise Stable) over 100s
10,000
Counts/Divs
Signal Filter Dynamic recursive type user programmable

 

Amplifier Modules

0.1-5.1V (3 Wire)

Parameter Min Typical Max Units/Notes
Electrical & Environmental
Supply Voltage Range 8.5 12 28 Volts
Operating Current
23
mA@350 Ohm
Operating Temp Range -40
85 ºC
Storage Temp Range -40
85 ºC
Reverse Polarity Protection

-30 Volts
Measurements
Output Voltage Range 0.1
±5.1 Volts
Band Width DC
1000 Hz
Linearity
0.02
%FR
Zero Temp Stability

0.0009 0.0025 ±%FR/ºC
Span Temp Stability

0.0025 0.0064 ±%FR/ºC

 

0.1-10.1V (3 Wire)

Electrical & Environmental
Supply Voltage Range 13 24 30 Volts
Operating Current
23
mA@350 Ohm
Operating Temp Range -40
85 ºC
Storage Temp Range -40
85 ºC
Reverse Polarity Protection

-30 Volts
Measurements
Output Voltage Range 0.1
+10.1 Volts
Output Load 5000

Ohms
Band Width DC
1000 Hz
Linearity
0.02
%FR
Zero Temp Stability

0.0009 0.0025 ±%FR/ºC
Span Temp Stability

0.0025 0.0064 ±%FR/ºC

 

±10V (4 Wire)

Electrical & Environmental
Supply Voltage Range ±13 ±15 ±15 Volts
Operating Current
23
mA@350 Ohm
Operating Temp Range -40
85 ºC
Storage Temp Range -40
85 ºC
Reverse Polarity Protection

-30 Volts
Measurements
Output Voltage Range -10
+10 Volts
Output Load 5000

Ohms
Band Width DC
1000 Hz
Linearity
0.02
%FR
Zero Temp Stability

0.0009 0.0025 ±%FR/ºC
Span Temp Stability

0.0025 0.0064 ±%FR/ºC

 

±10V (3 Wire)

Electrical & Environmental
Supply Voltage Range 14 15 18 Volts
Operating Current
30
mA@350 Ohm
Operating Temp Range -40
85 ºC
Storage Temp Range

-30 ºC
Reverse Polarity Protection


Volts
Measurements
Output Voltage Range -10
+10 Volts
Output Load 5000

Ohms
Band Width DC
1000 Hz
Linearity
0.02
%FR
Zero Temp Stability

0.0009 0.0025 ±%FR/ºC
Span Temp Stability

0.0025 0.0064 ±%FR/ºC

 

4-20mA (3 Wire)

Electrical & Environmental
Supply Voltage Range 10 24 30 Volts
Operating Current 27
43 mA@350 Ohm
Operating Temp Range -40
85 ºC
Storage Temp Range -40
85 ºC
Reverse Polarity Protection

-30 Volts
Measurements
Output Current Range 4
20 mA
Output Load

500 Ohms
Band Width DC
1000 Hz
Linearity
0.02
%FR
Zero Temp Stability

0.0009 0.0025 ±%FR/ºC
Span Temp Stability

0.0025 0.0064 ±%FR/ºC

 

 

4-20mA (2 Wire)

Electrical & Environmental
Supply voltage Range 7.5 24 30 Volts
Operating Current 4
20 mA (2 wire)........
Operating Temp Range -40
85 ºC
Storage Temp Range -40
125 ºC
Reverse Polarity Protection

-30 Volts
Measurements
Output Current Range 4
20 mA
Output Load

800 Ohms
Band Width DC
1000 Hz
Linearity
0.002
%FR
Zero Temp Stability

0.001 0.005 ±%FR/ºC
Span Temp Stability

0.007 0.014 ±%FR/ºC

 

 

 

PC-USB module

Setup and Single Channel Logging

usb software

(Click here to download software V2.0.01)

(and it's free!)

 

PC-USB module

Multi Channel Logging Software

usb adapter 24ch logging

(Click here to download software V1.1.4)

(and this is free too!)

Note: Linearity and Temp data refer to the performance of the module only. Refer to load cell specification for load cell data.